Repair Parts -- new and used -- moderated newsgroup for trading   >   Hand Tools   >   Pliers   >   Drager draeger cms analyzer gas datalogging detector

Drager draeger cms analyzer gas datalogging detector


For Sale: Drager draeger cms analyzer gas datalogging detector


Subject Drager draeger cms analyzer gas datalogging detector
Ad is submitted by poster: Drager CMS Analyzer Gas Datalogging Detector
* In very good condition ( see pictures)
* Comes with 1 leather case holder for gas detector and 1 leather case holder for up to 3 chips
* Does not come with any chips
* Copy and paste for more specific information:
* http:// /pdf/cms.pdf
Accurate gas measurements are made easier with the Draeger CMS. This new generation spot-check detection device is literally as easy as 1-2-3 to operate. Simply insert one of the 55 chemical specific Draeger-CMS-Chips into the Analyzer and follow the instructions on the display as to when to move the slide switch. TWA levels are typically analyzed in 1-2 minutes. Upon completion of this process, the concentration is indicated on the LCD display.
* Digital Display of Results
* UL, CSA, and MSHA Approved
The system is based on Draeger's 60+ years of dry chemical reaction technology used in Draeger-Tubes®. However, the CMS advanced electronics and sampling system delivers accuracies of +/- 4 to 10% of measured values for most gases and vapors. CMS does not require gas calibration. All measurement and calibration information is stored on a bar code on the CMS Chip. An electronics and leak check is performed before each measurement so you are assured of accurate indications every time. Operating on 4 "AA" cells, the CMS will deliver about 100 measurements per battery change. Popular applications include TWA screening, confined space entry, and emergency response
The CMS combines substance specific measuring Chips with an electronic based Analyzer for an easy to use spot-measurement system. The 10 capillaries in each Chip are filled with a reagent system based on Draeger's 60+ years of colorimetric chemistry expertise. The analyzer combines a revolutionary optical system for analyzing the color reaction with a mass flow controller and pump system that provides unbeatable reproducibility.
The CMS Analyzer requires no warm-up time. After taking a test, the results can be reported as quickly as 20 seconds. Higher concentrations, which pose a greater hazard, are reported faster than trace background levels. This increases the safety of using the CMS system.TWA and action levels are typically analyzed within 1-2 minutes. After providing the measurement results, the CMS is immediately ready for another test or another Chip for further analysis of the environment.
The expertise of Draeger's worldwide experience in industrial gas measurement has come to focus in the CMS. This is combined with a photo-optical controller that measures the speed of the chemical reaction, thus eliminating the human objectivity. Unlike other systems that rely on the volume of air, the CMS pulls the same mass of air through the capillary every time. The mass flow controller automatically compensates for changes in atmospheric pressure.
When you need to know exactly what is there, CMS is the tool to provide you those answers. The chemistry is chosen to provide the best results possible. The capillaries of several chips have multiple levels (Yes, even in something that small!) to help eliminate cross sensitivity or derive a specific measurement of the targeted chemical.
The Chip consists of 10 measurement capillaries filled with substance-specific reagent systems. The gas type, part number and batch number are printed on the chip. A printed barcode on the chip, read by the analyzer optics, contains information about gas type, measuring range and measuring time required for completing the measurement. Each chip is calibrated during manufacturing and is valid for two years.
The CMS is literally as easy to operate as 1-2-3. Making analysis is as simple as turning the unit "on" (moving the slide position to position 1), then following the plain language instructions on the display to load the Chip and move the slide selector to positions 2 and 3. Operating the CMS could not be easier because this is the exact same procedure for every Chip! Upon completion of analysis, the CMS Analyzer shows the concentration in the display. Any misinterpretation of the results is eliminated by the unambiguous digital display of the concentration.
The CMS Analyzer does not require gas calibration! All calibration information is stored on the bar code of the CMS Chip and automatically downloaded to the analyzer when inserted. An electronic system self test is performed every time the Analyzer is switched ON, and a sampling system test is performed before each test. You are always assured that the CMS system is operating properly. Operating on alkaline batteries means that there are no worries about charging or battery memory. CMS is gas detection made simple.

repair--parts.com bears NO responsibility for this ad. Please report ads that do not follow our rules (on front page). Posted By: Kristie Fowler
Contact: K-Fowler@repair--parts.com (Kristie Fowler) (this is a temporary forwarding address).




Drager draeger cms analyzer gas datalogging detector Drager draeger cms analyzer gas datalogging detector